piotres


Membre
Messages : 369

lundi 21 octobre 2013 à 00:04:48     
Hello

Last time I've repaired 3 units :

-small LD unit based on NL11F
-Mach 2 GT in custom alu-frame housing
-"big" LD unit based on rotary.

All units from one Denmark owner. Owner of units supply me some parts needed for mods + I make new suction lines with new evaps.

Owner do not want any visual mods of units, just to make them working again.


BIG SS:
-new 110cm long suction line by me , evaporator 54mm
-mounting second conder (supplied by owner of unit)
-chaning compressor to brand new LG 14.3k BTU
-R507


Prometeia Mach 2 GT:
-changing suction line to new, 42mm evaporator
-R507
-new pipes and drier


Small LD unit:
-new suction line by me,42mm evaporator
-R507
-new drier

Rotary compressor from big LD unit have been "dead" as owner said before work, but I have checked it and it work fine :yepp::.

So I make 4th unit basing on that compressor + black ECO condenser supplied by owner + one of old LD's suction line (check it for leaks + redone insulation). Those will be new GPU unit .


Final results (unloaded and loaded temperatures) :

Image

Nice box for transport DK->PL .

Image

Brand new LG NJ282PAD for big unit.

Image

Image

Some shiny and red stuff made by me .

Image

Image

Big unit done. Result @315W.

Image

Image

Small LD unit done. Result @280W.

Image

Image

And Mach 2 done . Result @280W.

Image

Image

Image

Image

Image

Image

4th unit based on parts which left from mods + "spare" condenser. :up:Result @315W.

Image

And all ready to go PL->DK .

Regards