Connexion
·
INSCRIPTION
·
Site
Recevoir à nouveau l'e-mail de validation
Forum Cooling-Masters
>
Cooling-Masters Worldwide
Big 2 stage cascade by piotres (2x 2+CV)
Ajouter ou retirer ce sujet de vos favoris
·
Suivre ce sujet
·
Imprimer ce sujet
Bas de page
Page précédente
Page suivante
piotres
Membre
Messages : 369
dimanche 25 septembre 2011 à 13:21:03
Hello
I'm making currently 2 stager with monsterous big 230V 1PH rotaries
2 rotaries over 25K BTU (2+HP).
+4 pressure gauges, 2 controllers, bypass, 2x cut-off, big expansion tank, 2 plate HXes (one as SLHX on 2nd stage).
Case with 4mm thick steel baseplate (because each compressor is over 25kg
).
It'll be worklog
.
Today I plan to screw all parts to baseplate
Regards
Peter
Google
piotres
Membre
Messages : 369
mardi 27 septembre 2011 à 01:27:44
Sk_rmouche
Apprenti Aigri
Messages : 17926
jeudi 29 septembre 2011 à 15:14:47
Looks great as usual, but what's the purpose of the little condensor ? Desuperheater of the second stage ?
piotres
Membre
Messages : 369
vendredi 30 septembre 2011 à 01:39:03
Yes, it's desuperheater for 2nd stage .
Plate HXes brazed
:
piotres
Membre
Messages : 369
dimanche 09 octobre 2011 à 01:33:28
I must change compressor on 1st stage for brand new Toshiba approx 28000BTU - "old" one was light used compressor, newertheless is has a leak (yes, leak on compressor :-O - first time I've seen that) on top, near electric connections. After I finish that project I try to weld and reapair it, now it has gone to shelf in mine workshop.
so now 2 brand new and BIG rotaries in the cascade :yepp: .
Old one unbrazed .
New one mounted
.
Cascade is 100% brazed, during some next days I plan loadtests
.
piotres
Membre
Messages : 369
vendredi 21 octobre 2011 à 01:39:58
After some complications (bad oilseparator - mixed discharge and suction ;/) and removing SLHX (it hadn't performed well in this cascade), I have made it running fine
.
Today approx -100C@315W with "cloth" pipe insulation
on one thermomether.
and -103C same time on another one .
On this color I plan to spray pipes this weekend
.
Sk_rmouche
Apprenti Aigri
Messages : 17926
vendredi 21 octobre 2011 à 12:24:13
quite impressive powerful cascade, what about the compressor and discharge temp, especially at second stage ?
piotres
Membre
Messages : 369
samedi 22 octobre 2011 à 02:04:50
I test it in 11*C ambient, pressures were approx 11 bara on 1st stage and 12 bara on 2nd stage fully loaded. I haven't measured temperature of pipes and compressor- compressors were quite hot, like almost always rotaries are
.
Sk_rmouche
Apprenti Aigri
Messages : 17926
samedi 22 octobre 2011 à 10:10:25
Okay
11C ? And with hot summer temps, you're expecting the worse ?
piotres
Membre
Messages : 369
jeudi 27 octobre 2011 à 01:30:51
Pipes painted, insulation done, most of electric work done
:
Regards
Peter
piotres
Membre
Messages : 369
lundi 28 novembre 2011 à 16:12:30
Finished a long time ago, but I haven't got time to upload pictures
:
Unloaded temperatures
. Carel controller on 1st stage shows around 8*C higher temperature than real, and that's end of it's probe tune area :shakes:.
Loaded with 315W dummyload .
Sound level loaded .
Black cascade and mine black cat
.
Regards
Peter
Google
Haut de page
Page précédente
Page suivante
Forum Cooling-Masters
>